Manufacturer item no.: 140246The DOL 10 is a simple temperature sensor. This sensor is well suited for use in environments that require a robust design and fast response time.The temperature sensor is used to measure the inside and outside temperature and has an accuracy of + 0.5 °C.The sensor has a temperature range of minus 40 to plus 60 °C and is protected according to IP67.The DOL 10 comes with a 1.5 meter cable. (Optional 5 meter cable, please inquire)TECHNICAL DATAelectricMeasuring range -40°C to +60°CAccuracy ±0.5°CEnvironmentAmbient temperature, operation and storage -40°C to +60°CProtection class IP 67sensor properties-40℃ 82.50kΩ 8.08V0°C 32.91kΩ 6.37V60°C 6.59kΩ 2.68V
Manufacturer item no.: 140263
The DOL 104 is a high precision relative humidity sensor. The sensor has an analogue output with very low output resistance and full protection against short circuits and cable faults. The special sensor element and the integrated filter enable use in livestock stables with a constantly high level of humidity. A protective cap is also available so that the sensor does not have to be removed when cleaning the barn.
Other models available on request:140279 DOL 104 humidity sensor 1-3V140273 DOL 104 humidity sensor 4-20mA140276 DOL 104 Humidity sensor 0.5-3V Rotem 8C
TECHNICAL SPECIFICATIONS
Measuring range 0 – 100% RH
Accuracy 2% RH (40-85%), 3% RH (10-95%) at 0-40°C *
Output signal 0.1V / % RH
Supply voltage 11 – 30 V DC
Supply current 12 mA no load 35 mA
max load Load > 500Ω - < 10MΩ
Recommended burden ≥ 100 kΩ
Output current 20 mA (current limited)
Output impedance < 1Ω
Temperature, operation and storage - 40 °C - 60 °C
IP classification IP 67
Cable 2 m. 3 x 22 AWG / 0.34 mm2
max. cable length/ 100 m 0.75 mm2 200 m 1.50 mm2
After direct exposure to water and condensation, a period of time with less than 80% relative humidity is required for a correct measurement.
Other variants available:
0-5V 0.05V / %RH
0-3V 0.03V / %RH
Similar to illustration
Manufacturer item number: 140308
DOL 111 is an optical rain detector. It has built-in optical probes for rain detection and comes with a 30-meter cable for easy installation.
To ensure automatic closing of inlets in case of rain for example in cattle stables, DOL 111 rain sensor can be connected to a climate computer.
DOL 111 rain detector can give a signal when it rains over or below 6.35 mm/hour (1/4”/hour). The rain sensor can be adjusted to stop detection 30 sec. to 5 min. after last drop. The sensor can be used in temperatures between minus 40 and plus 60 degrees Celsius.
The rain detector is made of UV-resistant polycarbonate, UV-stable ABS, stainless steel, and has a silicone O-ring to protect the circuit board from rain.
The sensor can also be used for other detection purposes.
DOL 111 is designed to override cycle programs, stopping the system during rainfall, and keeping it off for a while after rain has fallen. Thus, it can be used with irrigation controllers for stopping sprinklers at the field e.g. Irrigation will resume once the sensor dries out or it rains below 6.35 mm/hour.
Technical data:
Supply voltage 10-15 VDC / 15 mA
Output signal relay NO 1A 24 VDC
Sensitivity medium: 6.35 mm/hour
Stops detection 30s to 5mins after the last drop
Cable 30m (4 x 22AWG / 0.34mm)
weight 1500 gr
Manufacturer item no.: 140382
DOL 112-PT100 is a simple cost-effective temperature sensor. The sensor is a robust sensor with the high quality known from other dol-sensors’ sensor solutions. Thus, DOL 112-PT100 is well suited for use in environments where a sturdy design is required.
The temperature sensor can operate in temperatures between minus 40 and plus 100 oC and can be used for measuring both inside and outside temperatures.
DOL 112-PT100 is IP 68 protected, which means that it is dust tight and has total protection against water ingress, up to and including complete submersion below one meter and for more than 30 minutes.
The sensor has an accuracy of +0.5 oC and comes with a 2-wire 1.4-meter ø5 mm cable.
TECHNICAL DATAelectricMeasuring range -40°C to +100°CAccuracy ±0.5°CTolerance class B, F0.3Time constant T63 5 min. at 0.5 m/s air speedEnvironmentAmbient temperature, operation and storage -40°C to +100°CProtection class IP 68sensor properties-40℃ 84.27Ω0°C 100Ω60℃ 123.24Ωsensor dataTwo-core cable, length 1.40 mSensor Ø14, length 75mm
Manufacturer item no.: 140252
DOL 114 is a high-precision sensor for measuring relative humidity and temperature. The sensor was developed for use in livestock farming, but it is suitable for numerous industrial purposes. The sensor has two analogue outputs with very low output resistance and full protection against short circuits and cable faults. The special sensor element and the integrated filter enable use in livestock stables with a constantly high level of humidity. Depending on requirements, the sensor can be equipped with an integrated termination socket or a cable and with a specially adapted specification range. The sensor is controlled by a microprocessor and has a two-color LED diode for displaying operating status and fault diagnosis. The sensor is available with an extinguished diode on request.
Other variants available on request: 140260 DOL 114 humidity & temp. sensor 0-60°C 140253 DOL 114 Humidity & temp. sensor 5m cable 140254 DOL 114 humidity sensor including plug 0-10V 140282 DOL 114 RH & temp. sensor 0.5-3V red
TECHNICAL SPECIFICATIONS Measuring range:
Humidity: 0 – 100% RH 17 – 100% RH*
Temperature: - 40°C – 60°C 0 - 60°C
Accuracy :
Humidity: ± 2% RH (40-85%) ± 3% RH (10-95%) at 40°C
Temperature: +10°C - 40°C:± 0.5°C
- 30°C - 60°C: ±1.5°C Output signal:
Humidity: 0.1V/%RH
Temperature: 0.1V/°C; 0°C at 4V
Time constant T63: 20 s at 0.5 m/s air speed 6 min at 0.5 m/s air speed
Electrical connection: 11 – 30 V DC
Current: 12mA no load / 55mA max load
Load: > 500Ω - < 10MΩ
Recommended load: ≥ 100 kΩ
Output current: 20 mA per output (current limit)
Output Impedance: <1Ω
Operating and ambient temperature, storage: - 40 °C - 60 °C
IP classification: IP 67
Cable: 2m. 4 x 22AWG / 0.34mm2
Maximum cable length 100 m at 0.75 mm2 200 m at 1.50 mm2
Illustration similar
Manufacturer item no.: 140292Plug connection for removing the sensors during cleaning work.A blind cap closes the plug connection during cleaning.Suitable for DOL 16/104/114
Manufacturer item no.: 140331
For measuring the CO2 content in the air. Supplied with M12 connector and sealing plug and protective cap for DOL 119. DOL 119 is a sensor for measuring the prevailing level of carbon dioxide/CO2. The sensor is used for climate monitoring via the CO2 content of the barn air. The measurement range of the sensor is based partly on monitoring the comfort zone of the animals and partly on monitoring possible error conditions in direct combustion houses. The sensor has two analogue outputs, with 0-10V power and 0-5V power respectively. Both are with low output impedance and full protection against short circuits and cable faults. The sensor is protected by a stable housing and its placement behind a carefully selected filter. The sensor is equipped with a cable and a protective cap so that it is not damaged during washing and disinfection work. The sensor must be installed in the middle of the barn building. TECHNICAL SPECIFICATIONS
Exit:
Measuring range (output 1) 0 - 10 VDC
Measuring range (output 2) 0 - 5 VDC
Limited output current per port 20 mA
Output impedance <1Ω
Recommended load impedance >100 kΩ
Max. cable length @ 0.75mm2 100 m
Max. cable length @ 1.50mm2 200 m
Load impedance 0.5 – 10000kΩ
CO2 – Output 1:
Measuring range 0-10000ppm
Output resolution 0.001V/ppm CO2
Accuracy 400 – 10000ppm 50ppm + 5% of reading ppm
Temperature stability (0-50°C) + 2.5 ppm/oC
Time constant: T63 2 minutes at 0.5 m/s air velocity
CO2 – Output 2:
Measuring range 0 - 5000 ppm
Output resolution 0.001V/ppm CO2
Accuracy 400 – 10000ppm 50ppm + 5% of reading ppm
Temperature stability + 2.5 ppm/oC
Time constant T63 2 minutes at 0.5 m/s air speed
General:
Power supply: 13.5 - 30 VDC
Supply Current: No Load 8mA, Max Load 55mA
Temperature, operation: CO2: CO2 valid 0 - +50 oC
Temperature, operation: -40 - +60 oC
Temperature, storage: -40 - +70 oC
IP protection class: IP67 (DIN 40050-9)
NEMA 1, 3, 4, 6
Cable Length: 2m
Cable conductor size: 4 x 0.34 (4 x AWG22) mm2
Manufacturer item no.: 140261Protective cap for the DOL 119/139, which ensures that the sensor is not damaged during cleaning work, for example.1 set contains 5 pieces
Manufacturer item no.: 140200 (Alternative for 140207, 140203, 140295)The DOL 12 temperature sensor is a simple temperature sensor. This sensor is well suited for use in environments where a robust design is required and can be used in temperatures between minus 40 and plus 100 °C.The sensor can be used to measure both indoor and outdoor temperature and is supplied with a 1.5 meter 2-wire cable.The DOL 12 sensor is IP 67 protected and has an accuracy of +0.5 °C.TECHNICAL DATAelectric Measuring range: -40 °C to +100 °C Accuracy: ±0.5°C Time constant T63 5 min at 0.5 m/s air speedEnvironment ambient temperature. Operation and storage: -40 °C to +100 °C protection class. Electronics: IP 67 Length: diameter 75mm. 14mm Two-core cable. 1.4m. Diameter 5mmsensor properties -40℃ 82.50kΩ 8.08V 0°C 32.91kΩ 6.37V 60°C 6.59kΩ 2.68V
Manufacturer item no.: 140283
DOL 139 is a sensor for measuring carbon dioxide/CO2, relative humidity and temperature. The sensor is used to monitor and control homes and industrial environments. The sensor is protected by a sturdy housing and behind a carefully selected filter. The sensor comes with cable and a cap to protect the sensor -ring washing and disinfection.
TECHNICAL SPECIFICATIONS
Output voltage range: 0 - 10 VDC
Limited output power per port: 20 mA
Output Impedance: <1Ω
Recommended load impedance: >100 kΩ max.
Cable length: at 1.50 mm2 200m
Load Impedance: >0.5kΩ
Relative humidity: measuring range 0-100%RH
Resolution: 0.1V/%RH
Accuracy: +10 °C - +40 °C (40-80%RH)+/-3 %RH
Accuracy: 10% RH - 95% RH +/-3 + 0.02 x measured value %RH
Time constant: T63: 4 min at 0.5 m/s air speed
Temperature measuring range: -40 – +60 °C
Resolution: 0.1V/AC
Accuracy: +10°C - +40°C +/-0.75°C
Accuracy 0°C - +60°C +/-1.5°C
Time constant T63 7 min at 0.5 m/s
Air velocity CO2 measurement range 0-10000ppm
Resolution: 0.001V/ppm
Accuracy: 400 - 10000 50ppm + 5% of reading
Time constant T63: 2 min at 0.5 m/s air speed
Supply voltage: 13.5 - 30 VDC
Supply current idle: 9 mA
maximum load: 105mA
Temperature operation CO2: 0 - +50 °C temperature,
Operation: -40 - +60 °C temperature,
Storage: -40 - +70 °C
IP classification: IP67 (DIN 40050-9)
NEMA-1, 3, 4, 6
The DOL 16 is a sensor for measuring light intensity in lux. The sensor was developed for the harsh operating conditions in livestock housing, but is also suitable for numerous industrial purposes. Light intensity or illuminance plays an important role in optimizing broiler growth and laying hen egg production. Active control of the light intensity using the DOL 16 helps to increase production and save energy. The sensor has two 0-10 V analogue outputs with very low. output resistance and comprehensive protection against short circuits and cable faults. The sensor is controlled by a microprocessor and has a two-color light-emitting diode (LED) for communication of operating status and error diagnostics.
TECHNICAL SPECIFICATIONS
Measuring range:
Output 1: Lux 0-100*
Output 2: 0-1000
Accuracy:
Output 1: 5 - 100 lux +/- 4% at 0 - 40 oC (32 - 104 °F)*
Output 2: 25-1000 lux+/-8% at 0-40°C (32-104°F)
Output signal :
Output 1: 0.1V / 1lux
Output 2: 0.1V / 10lux
Time constant sec. Typ. 2 max. 15
Supply voltage (Usupply) V DC 11 - 30
Supply current mA 12 no load55 max load
Load Ω >500 – 10M
Recommended burden kΩ >100
Output current mA 20 per output (current limited)
Output impedance Ω<1
Temperature, operating °C (°F) -40 – 60 (-40 – 140)
IP rating IP (NEMA) 67 (6)
Cable connection (M12 version)
M12 male (female) with 2 m (6.6 feet) 4 x 0.33 mm2 (22AWG) cable
Cable max. cable length m 100 0.82 mm2
Illustration similar
Manufacturer item no.: 140245Protective housing for operating humidity sensors under outdoor climate conditionsProtects the sensor from direct rain and sunlightSuitable for DOL 16/104/114
Manufacturer Art. No. 140231DOL 19 is a carbon dioxide/CO2 sensor intended for measurements in barn and industrial environments. The measuring range of the sensor has been carefully selected to ensure the comfort of the animals and also to monitor possible error conditions in direct combustion housing. The sensor is protected by a sturdy housing and is behind a carefully selected filter. The sensor is supplied with a plug and cableTECHNICAL DATAReadings: Measuring principle Non-Dispersive Infrared Technology (NDIR) Measuring range: 0...10,000 ppmAccuracy at 25 °C (77 °F) and 1013 mbar: 0-7000: 50ppm +5% of reading 7,000-10,000: 100ppm +5% of reading Temperature dependency: type. 1ppm CO2/°C (-20…45°C) Sample rate: Approx. 15 sec Analog output: 0...10,000 ppm voltage 0 - 10 V and current 4 - 20 mA Load: > 10 kΩ ≤ 500 Ω Recommended burden: ≥ 100 kΩ 500 ΩGenerally Supply voltage: SELV 15 – 35 V DC SELV = Safety Extra Low Voltage Power supply voltage output: Typ. 16mA current output: max. 36mA max. 0.5 A in 0.3 s max. 0.5 A in 0.3 s Warm-up time: < 5 min Housing / protection class polycarbonate / IP54 Electrical connection Cable with M12 connector cable 2m. 4 x 22AWG / 0.34mm2 Electromagnetic compatibility EN 61326-1 EN61326-2-3 working temp. and conditions -20...60 °C (-4...140 °F) 0...100 % RH (non-condensing) storage temperature. and conditions -20...60 °C (-4...140 °F) 0...95 % RH (non-condensing)
Manufacturer item no.: 140312The DOL 51 is an ammonia sensor specifically designed for continuous measurement of ammonia concentration (NH3) in high humidity applications, expanding the capabilities of the award-winning DOL 53.Survives even the toughest conditionsThe innovative design of the DOL 51 allows the operation of this sensor even under harsh conditions with an extremely high humidity of 95 - 100%, e.g. in animal stables. Air is directed to the meter inlet through a heated air duct to prevent condensation. Like all sensors from dol-sensors, the DOL 51 has also been extensively tested and has proven to have a long service life without the need for calibration.Precise ammonia measurementsThe DOL 51 provides accurate ammonia measurements in concentrations up to 50 ppm and has negligible cross-sensitivity to other gases. The DOL 51 is mounted directly in the air flow without the need for additional hoses or pumps.TECHNICAL DATA Supply voltage: nominal voltage 24 V (22 V to 26 V DC); DC Current consumption: <200mA Signal transmission to the evaluation unit: 0 - 10 V and 4 - 20 mA corresponds to 0 to 50 ppm NH3 Measuring range: 0 to 50 ppm NH3 Signal transmission resolution: 0.2 V/ppm NH3, 0.32 mA/ppm Accuracy: 1.5 ppm or ±10% of reading Response time T50: ≤30 seconds Long-term drift: < ±10% of the measured value / year Cable type: 5-adri, 6 m Ambient temperature (operation): 0 °C to +50 °C Ambient Humidity (Operating) :15% to 100% RH Air pressure (operating): 700 hPa to 1300 hPa Ambient temperature (Larger): -20 °C to +60 °C Dimensions: H x W 155mm x 75mm Material housing, DOL 53: PA Protection IP65
Manufacturer item no. 140247The award-winning DOL 53 is a sensor designed for continuous measurement of ammonia (NH3) concentration in livestock housing. The negative effects of high ammonia concentrations in livestock housing are well known. With the introduction of the DOL 53, the farmer is finally able to continuously measure the ammonia concentration and take corrective action when ammonia concentrations rise. The DOL 53 offers accurate measurements at both low and high concentrations, negligible cross-sensitivity with other gases and a long service life without the need to calibrate the sensor. The DOL 53 can be installed directly in the livestock barn without pipes and pumps. The DOL 53 measures ammonia concentrations between 1.5 and 100 ppm, with an output range between 0 and 10 V.
TECHNICAL SPECIFICATIONS
Supply voltage: nominal voltage 24 V (18 V to 30 V DC); DC < 0.2 Vpp
Current consumption: <10mA
Signal transmission to the evaluation unit: 0 V to 10 V corresponds to 0 to 100 ppm
Measuring range: 0 to 100 ppm NH3
Signal transmission resolution: 0.5 ppm
Accuracy: 1.5 ppm or ±10% of reading
Response time T50: ≤30 seconds
Long-term drift: < ±10% of the measured value / year
Cable Type: 3 core
Ambient temperature (operation): 0 °C to +50 °C
Ambient Humidity (Operating) :15% to 95% RH
Air pressure (operating): 700 hPa to 1300 hPa
Ambient temperature (Larger): -20 °C to +60 °C
Dimensions: H x W 155mm x 75mm
Material housing, DOL 53: PA
Manufacturer item no.: 140232The DOL 58 measures wind direction, wind speed and air pressure. wind speedand direction are measured using ultrasound,which means that the weather sensor has no moving parts.By doing away with the impeller and wind vane of a typical weather sensorthe DOL 58 is extremely robust, reliable and easy to maintain.The DOL 58 is available with output ranges between 0-10V or 4-20mA.There is also a version with temperature output instead ofair pressure available.
DOL 58 Includes: Weather sensor Connection box 5m/16feet and 30m/98feet cable for connection between weather sensor and connection box Mounting bracket for the weather sensor
Manufacturer item no.: 140237The DOL 61 display and alarm unit can be used with all sensors with a 24 VDC supply voltage and outputsbe used with 0-10 VDC or 0-20 mADC. DOL 61 has a relay that can be activated in such a waythat it will be activated when a certain entry criterion is met. The relay can for exampleUsed to sound a horn or flash a light when ammonia levels are low in a stallexceeds 50ppm. DOL 61 can supply a sensor with 24 VDC.TECHNICAL DATAmains voltage Supply voltage, input 100-240VAC Frequency 50/60Hz Current consumption input <110 mA @ 230VACsensor interface Supply voltage, output 24VDC ±5%: 40mA. Max voltage 100mA Analog input 0-10VDC or 0-20mADC selectable by jumperexits touch display Relays, 1 pc. Com. Make 10A @ 125VAC 5A @ 30VDC 5A @ 250VAC USB data outputdata storage Mini SD card. Stores data for 300 days (continuously deleted). The data is saved every 30 seconds with a decimal number.environmental conditions Operating temperature 0 oC to +45 oC Humidity (operating) 10% to 90% RH Air pressure (operating) 700 hPa to 1300 hPa Temperature (storage) -20 oC to +60 oCmechanical properties Dimensions H x W x D: 152 x 162 x 261 mm Weight (about): 800g Chemical resistance Typical cleaning agents, disinfectants, alcohol, surfactants, peracetic acid, soap Degree of protection IP 56 Conformity CE