Manufacturer item no.: 140237
The DOL 61 display and alarm unit can be used with all sensors with a 24 VDC supply voltage and outputs
be used with 0-10 VDC or 0-20 mADC. DOL 61 has a relay that can be activated in such a way
that it will be activated when a certain entry criterion is met. The relay can for example
Used to sound a horn or flash a light when ammonia levels are low in a stall
exceeds 50ppm. DOL 61 can supply a sensor with 24 VDC.
TECHNICAL DATA
mains voltage
Supply voltage, input 100-240VAC
Frequency 50/60Hz
Current consumption input <110 mA @ 230VAC
sensor interface
Supply voltage, output 24VDC ±5%: 40mA. Max voltage 100mA
Analog input 0-10VDC or 0-20mADC selectable by jumper
exits
touch display
Relays, 1 pc. Com. Make
10A @ 125VAC
5A @ 30VDC
5A @ 250VAC
USB data output
data storage
Mini SD card.
Stores data for 300 days (continuously deleted).
The data is saved every 30 seconds with a decimal number.
environmental conditions
Operating temperature 0 oC to +45 oC
Humidity (operating) 10% to 90% RH
Air pressure (operating) 700 hPa to 1300 hPa
Temperature (storage) -20 oC to +60 oC
mechanical properties
Dimensions H x W x D: 152 x 162 x 261 mm
Weight (about): 800g
Chemical resistance Typical cleaning agents, disinfectants, alcohol, surfactants,
peracetic acid, soap
Degree of protection IP 56
Conformity CE